High Efficiency 90 - 264 VAC telecom Equipment JPS250PS48C

High Efficiency 90 - 264 VAC telecom Equipment JPS250PS48C factory

Large Image : High Efficiency 90 - 264 VAC telecom Equipment JPS250PS48C

Product Details:

Brand Name :
Model Number :JPS250PS48C
Certification :Rohs,CE,ISO9000,3C
Place of Origin :Germany

Payment & Shipping Terms:

Minimum Order Quantity:1 piece
Price:0
Packaging Details:Carton /Standard packing
Delivery Time:1-5 days after payment confirmed
Payment Terms:T/T or Western U
Supply Ability:Please Contact us
Detailed Product Description

 

High Efficiency 90 - 264 VAC telecom Equipment JPS250PS48C


High Efficiency 90 - 264 VAC Telecom Power Supplies For Telecom Equipment JPS250PS48C


JPS250PS48C
 

200 W with Convection Cooling

High Efficiency - up to 88%

Meets 1U, Low Profile Requirements

AC OK & DC OK Signals

Zero Voltage Switching Technology

Remote On/Off & Remote Sense

Current Share
 

Model Number

JPS250PS48C

Manufacturer

XP POWER


 

Input

Input Voltage            90-264 VAC (170-370 VDC)

Input Frequency          47-63 Hz

Input Current            2.75 A/1.40 A max at 115 VAC/230 VAC

Inrush Current           30 A at 115 VAC, 60 A at 230 VAC

Power Factor            0.99 typical

Earth Leakage Current     2.0 mA max 264 VAC/60 Hz

Input Protection          Internal 5 A, 250 V fuse

 

Output

Output Voltage Trim     ±10% on output 1 only

Initial Set Accuracy     At 60% rated load ±1% on V1 & V2,

±5% on V3 & V4

Minimum Load         Single output models: No minimum load

required. Multi-output models, see note 4

Start Up Delay          2 s typical

Start Up Rise Time      80 ms typical

Hold Up Time          20 ms min at low line & rated load

Line Regulation         ±0.5% at rated load across input

voltage range

Load Regulation         ±1% for single output models & V1 & V2

of multi-output models, ±5% for V3 & V4

Transient Response      4% max deviation, recovery to within

1% in 500 μs for a 25% load change

Ripple & Noise          ±1% max pk-pk, 20 MHz BW

Overvoltage Protection   115-140% on single outputs & V1 of quad

output models, recycle input to reset

Overtemperature         Shuts down at +110 °C, auto recovery

Protection              measured internally

Overload Protection      110-130% of max rated load on all O/Ps,

trip & restart (Hiccup mode), auto recovery

Short Circuit Protection    Trip and restart (Hiccup mode)

Temperature             ±0.05%/°C

Coefficient

Remote Sense           Compensates for up to 0.5 V drop

Remote On/Off          On = Logic Low or Open, Off = Logic High

Current Share           Single wire current sharing on single

output models & V1 & V2 of multi-output

models (4 supplies can be paralleled)

Fan Output             5 V model: 5 V at 390 mA,

24 V model: 24 V at 80 mA,

all other models: 12 V at 112 mA

General

Efficiency               Up to 88%

Isolation                3000 VAC Input to Output

1500 VAC Input to Ground

500 VAC Output to Ground

Switching Frequency      120 kHz typical for PFC and PWM

Power Density            4.96 W/In3

Signals                 AC OK, DC OK, Remote On/Off

(see control and supervisory signals)

MTBF                  255 kHrs per MIL-HDBK-217F at +25 °C

 

 

Environmental

Operating Temperature     0 °C to +70 °C, (see derating curve)

Full power to +50 °C

Cooling                250 W with 18 CFM airflow

200 W convection cooling

Operating Humidity       5-95% RH, non-condensing

Storage Temperature      -20 °C to +85 °C

Operating Altitude        3000 m

Vibration               2 g, 10 Hz to 55 Hz,

3 mins/cycle for 30 mins each axis

 

EMC & Safety

Emissions             EN55022, level B conducted

FCC 20780, level B conducted

Harmonic Currents      EN61000-3-2

Voltage Flicker         EN61000-3-3

ESD Immunity         EN61000-4-2, level 3 Perf Criteria A

Radiated Immunity      EN61000-4-3, 10 V/m Perf Criteria A

EFT/Burst             EN61000-4-4, level 3 Perf Criteria A

Surge                 EN61000-4-5, level 3 Perf Criteria A

Safety Approvals        EN60950-1:2001, UL60950-1,

CSA C22.2 No. 60950-1-03,

CE Mark LVD

Tag :
Contact Details
Oriental Components Limited

Contact Person: Ms. Fiona Hong

Tel:86-0755-82717080

Fax:86-0755-82717052

Send your inquiry directly to us (0 / 3000)

Other Products

NOKIA CP816-AC C111134.C2B Communications equipment

HUAWEI RSU60E MA(934~960MHZ) Communications equipment

NOKIA BAS7-C C105007.E4A Communications equipment

NOKIA PSC6-CB C111179.B2A Communications equipment

Alcatel SERGL 3AL98269AA Communications equipment

HUAWEI SmartAX MA5608t 02120747 H831FCBB0 Communications equ